Analogue Device not ringing

 

We had installed a FAX connection on a FXS port, all was working fine but when you dialed the number the caller could not hear the call progress tone. On the CME side teh device would ring just fine. Initially we thought it maybe something to do with the PSTN but the following command solved the problem

#configure terminal
config)# voice call send-alert

“To enable the terminating gateway to send an alert message instead of a progress message after it receives a call setup message, use the voice call send-alert command in global configuration mode. To reset to the default, use the no form of this command.”